Pipe: /50-B-9

Plantcon
Pipe Design ValidationSoftware version 1.00
Project:Sample Project
Project number:(01223) 556666
Project description:PDMS Sample Released Project
Dato: 27 Apr 2001 Tid: 15:24
Following papameters used:
Fall minimum:1/100 = 0.5729Deg
Check for distance innerside Pipe to P0 in valve3 * Nominel Bore
Bend and Elbow radius bigger than1 * Nominel Bore
Legal length of tube pieces without fall 5 * Nominel Bore

Drain Error

Error found: TUBE refe: ELBOW 1 of BRANCH /50-B-9-B1 can not be drained
Error found: TUBE refe: /50-B-9-B1-TEE1 can not be drained
Error found: TUBE refe: /50-B-9-B1-TEE2 can not be drained
Error found: TUBE refe: /50-B-9-B1-TEE3 can not be drained
Error found: TUBE refe: /V119 can not be drained
Error found: TUBE refe: /50-B-9-B1-TEE5 can not be drained
Error found: TUBE refe: ELBOW 5 of BRANCH /50-B-9-B1 can not be drained
Error found: TUBE refe: ELBOW 7 of BRANCH /50-B-9-B1 can not be drained
Error found: TUBE refe: /50-B-9-B2 can not be drained
Error found: TUBE refe: VALVE 1 of BRANCH /50-B-9-B2 can not be drained
Error found: TUBE refe: ELBOW 1 of BRANCH /50-B-9-B3 can not be drained
Error found: ELBO ELBOW 3 of BRANCH /50-B-9-B1 can not be drained

Dead Leg Error

Error found dead leg between: /50-B-9-B1-TEE5 and: VALVE 1 of BRANCH /50-B-9-B2 Distance =1250.300048> ( 3 * 50 )
Error found dead leg between: =15392/5528and refe: =15392/142975 Distance =< ( 3 * 50 )
Error found: VALV VALVE 1 of BRANCH /50-B-9-B2 can not be drained
Error found: VALV VALVE 2 of BRANCH /50-B-9-B2 can not be drained
Error found dead leg between: =15392/5528and refe: =15392/142975 Distance =< ( 3 * 50 )
Error found: FLAN FLANGE 6 of BRANCH /50-B-9-B1 can not be drained

Bend/Elbow radius error

Error found: ELBO Name: ELBOW 1 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 2 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 3 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 4 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 5 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 6 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 7 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 8 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 9 of BRANCH /50-B-9-B1 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 1 of BRANCH /50-B-9-B2 radius = 38 < ( 1 * 50 )
Error found: ELBO Name: ELBOW 1 of BRANCH /50-B-9-B3 radius = 38 < ( 1 * 50 )